LoRa® HCA

Heat cost allocator with LoRaWAN®

LoRa EHKV


The HCA EURISII-LoRa® is available as a 2-sensor device with and without a remote sensor. With 2-sensor devices the room temperature is measured in addition to the radiator and the consumption is determined using the differential temperature. Therefore, these devices are more accurate and even less sensitive to manipulation attempts. In addition, various functions are implemented that avoid cold counting in summer. For the “self-reading” of the consumption values by the user, a check number for verifying the validity of the reading can also be displayed.

LoRaWAN® was implemented as the radio technology. The HCA is parameterized via an optical interface. Since the HCA is battery-operated and should have a service life of 10 years, the transmission frequency was limited to one transmission every 2-6 hours, which is sufficient for a consumption billing. For requirements in the area of data protection, the option has also been implemented to limit the transmission intervals to 1 telegram per day, or per 7 or 14 days via LoRa® radio.

Some important key data:

Radio system LoRaWAN®

2 sensors

Sabotage branding

Sending interval adjustable

Measurement pause can be activated for summer months

Duration 10 years

optionally with remote sensor

optical interface with PIN

double AES 128 encrypted

Variant with and without button.

Documents / software:

Datasheet version long

Data sheet version compact

LoRa Setup Tool

Activation APP Android

wM-BUS Gateway
The wM-Bus gateway receives wireless M-Bus protocols in T / C / S mode, filters them as required, stores them and sends them to a server via an IP connection.

The gateway has no mobile data connection. It only uses existing networks. The gateway is particularly suitable for stationary reception of wM-BUS protocols using an existing internet connection. Internet routers are usually already in place. Usually nothing needs to be changed on the router.
Simply plug the gateway into the router's USB connection (optionally with a USB power supply unit) and connect it to the router with a network cable.

The gateway can optionally be parameterized via a website, USB interface or via the wM-BUS gateway server.
The received wM-BUS protocols can be filtered in the device in advance according to manufacturer, medium code and / or according to individual IDs.
The gateway sends the received and filtered data to the server either immediately, hourly, daily or monthly.
The free "wM-BUS to TCP Gateway Server" or an application developed by the user can be used as a server.
Share by: